Glass u value chart. 6W/m²K Thermal Spacer add on U-Value = 1.
Glass u value chart (0. ENERGY STAR does not consider center-of %PDF-1. over laminated temp. The overall IGU U-factor can be determined using the EOG and COG values and will be affected by the IGU make-up, including spacer type, IGU gas fill type, coatings, overall thickness, etc. 25, or 4 (leaving off the units for brevity). 89 The gas mixture is assumed to consist of 90% argon and 10% air Alternatively, specify Pilkington Insulight™ Therm 1. What is a U Value? U Value is A measure of air-to-air heat transmittance (loss or gain) due to thermal conductance and the difference in indoor and outdoor temperatures. 8 operated by Lawrence Berkeley National Laboratory (LBNL) using International Glazing Database (IGDB) v102. 0. 12 8. 922. A number which describes, in specific terms, the ability of a material or assembly to transmit heat from outside to inside surfaces. As we have talked about in the post about types of insulations here different materials and types of insulations have different R-values. Out Refl. 27 . 14 Decorative Glass – Wrought Iron 2018 U-Factor / Solar Heat Gain Coefficient Chart. Values for each contribution by: U0 = (Uc 9·Acg + Ue ·Ae9 + U(A1) I (Acg + Aeg + A1) , (2) where the subscripts cg, eg, and f refer to, respectively, the center-of-glass, edge of-glass and frame. 10 equals an R-value of 10 (1 divided by 0. Just because a unit is triple glazed, it How Do You Calculate a Window’s U-Value? When calculating a window’s U-value, there are three key factors to consider: Uf Value: The frame’s thermal performance Ug Value: The glass panel’s thermal performance PSIG: The glass edge’s thermal performance These three aspects, along with a handful of other measurements such as the window’s opening A large amount of glazing configurations means the perfect glass can be yours. 6 0. 82 2. U Value: SHGC: Selectivity: Glass Type: Notes. , an Intertek Company (Intertek-ATI) was contracted to perform U- The method gives overall product An insulating glass unit comprising 4 mm Pilkington Optifloat™ Clear outer pane, 16 mm argon gas-filled cavity and 4 mm Pilkington K Glass™ inner pane has a centre pane U value of 1. It has 30% less weight than triple glazing windows. in glass u value is approx. 29 Pilkington Energy Advantage (2) Argon . 0 Walls, Above Grade Mass U-0. Departures of ±50% or more from these values may occur. In a standard one-inch insulating glass unit (IGU), Solarban® 60 glass offers an exterior To calculate R-value, divide 1 by the U-value figure. 48 SHGC 0. 37 SHGC. 26 in the Northern and North-Central climate zones. U-value is sometimes known as thermal transmittance. 0. Find out why in the seller's fact sheet on R-values. e. SOLAR HEAT GAIN COEFFICIENT (SHGC) Product Data Sheet Vitro Architectural Glass LEED® Credit Opportunities Possible Points LEED Credit Solarban® 90 Feature Path/Option Satisfied 18 Energy & Atmosphere (EA) Optimize Energy Performance Excellent SHGC, U-value and Tvis performance Whole Building Energy Simulation (Option 1) or Prescriptive Glass (in doors): The R-value for glass doors varies significantly based on the glazing type. Look for a higher R-Value for a more energy efficient product. The gas mixture is assumed to consist of 90% argon and 10% air. (4) The UV Transmittance is determined as an average for wavelengths 310 -380 nm. Solar Heat Gain Coefficient Table of U-Values . U-value scores typically range from 0. 063 R-15. 40 CENTER OF GLASS U-FACTORS & SHGC VALUES: SYRACUSE COMPANY : Author: Kathy Rung Created Date: 10/3/2016 4:52:02 PM 2009 IRC Only: In the 2009 IRC, the maximum U-factor value is 0. Less than or equal to. 3mm Clear 2. 1(1) through A107. WER & U-value Chart Windows & Doors Inliten 70mm System - Tilt N Turn Double Glazed Name Outer mm Glass Unit Spec Unit mm U-value (Uw) Solar Gain Air Leakage Label No A model 60 Float/Argon/Soft Coat/Warm Edge Spacer 28 1. Thus, a single-paned window’s U-Value with a basic aluminum frame is above 1, usually around 1. 15 12. 0mm) thick clear glass under the same design conditions. 3 0. 1 Argon and Krypton figures are based on a standard 90% and 92% fill respectively For multi cavity and other low-E combinations please contact Customer Service on 01207 288200 www. 2-hr-°F (low-e IG)-Edge of Glass (EOG) Typical value 0. As the u-value decreases, so does the amount of heat that is transferred through the glazing material. 50 1. The lower the U-Factor, the better for thermal performance. Importance of U-Value: NFRC emphasizes . It basically tells you how well a door or window insulates the home. 10). 063 U-0. Required Combination Types for Durable & Green Reinforced or Prestressed Concrete Elements U-Values are quoted in W/m²/K, rounded to the nearest 0. The U-value is the inverse of the R-value. uk Cavity Fill Unit make up (mm) Overall IGU thickness (3 x 4mm) Glass 1 Glass 2 (Toughened Testing Data Notes. All performance data is determined using LBL window 7. cooled air. It quantifies how well a material can insulate against heat loss or gain. 6 What is a U-Value? “U-value is the measure of the overall rate of heat transfer through a particular section of construction. Values include; Colour, Visible Light Transmittance and Reflections, UV Blockage, U-Value, SHGC, Selectivity ratio, Acoustics and Weight: AGG Performance Data - Glass Only. 0 chen. The R-Value is the thermal resistance of the window or patio door glass to heat flow. Measuring your home?s heat loss is not as complicated as you may think. However, the Types of Glass_____ 3 annealed Glass Heat-strengthened Glass Tempered Glass laminated Glass Insulating Glass Warm-edge spacer Tinted Glass vs. How to measure the U value. An insulating glass unit comprising 4 mm Pilkington Optifloat™ Clear outer pane, 16 mm argon gas-filled cavity and 4 mm Pilkington K Glass™ S GLASS SIZES AND OPTIMIZED U-VALUES U-VALUE U-VALUE METRIC IMPERIAL GLASS TYPE 2SPACER 2 (W/m . 030, we get an R-Value for the window of 3. 7 — that’s 12. 7 Clear Hardcoat Numbers: U-Factor / Solar Heat Gain Coefficient x: Indicates Product Availability Indicates Product is Energy Star Qualified in Northern Zone Indicates Product is NOT Energy Star Qualified Glass Designs 6'8" Height Doors Glass Size (Inches) 25x66 25x51* 10x51 25x42* 21x35 25x35 15x38 10x42 10x8 Decorative Glass. The table lists U-values for walls, doors, roofs, floors, windows, and cold mass materials like concrete and steel. 25 SHGC 0. 47 0. 20, which NFRC-certified labs calculate using thermal measurements from the center and edges of the glass, the frame and along any dividers the window may have. 60 U-factor, while mixed climates (with high temperatures in summer and low temperatures in winter), require a U-factor at or equal to 0. 9 Light to Solar Gain ratio (LSG) 0. Clear 6. Energy-Efficient External Doors. The end value is in watts per square metre per Kelvin W 4 Values are based on comparison of Renewal by Andersen® double-hung window U-factor to the U-factor for clear dual pane glass non-metal frame default values from the 2006, 2009, 2012, 2015 and 2018 International Energy Conservation Code "Glazed Fenestration" Default Tables. Thus, if the thickness is 1 inch, and the K-value is 0. The lower the U-value, the greater the polycarbonate’s resistance to heat flow and the higher the insulating value. 69. (5) UV Damage Weighted Transmittance (Tdw) is the weighted average for wavelengths 300 - In this section, we will explore the difference between two of the most significant glass performance measures; U-Value and R-Value. A lower U-Value indicates better insulation properties and is particularly important in colder climates where thermal insulation is critical. 4 %âãÏÓ 2265 0 obj > endobj xref 2265 31 0000000016 00000 n 0000002149 00000 n 0000002496 00000 n 0000002643 00000 n 0000003095 00000 n 0000004072 00000 n 0000004123 00000 n 0000004162 00000 n 0000010342 00000 n 0000010947 00000 n 0000011348 00000 n 0000011784 00000 n 0000011863 00000 n 0000012455 00000 n The Center-of-glass U-value is a measurement of ONLY one location on the glass. It is Pella manufacturers stipulate that ratings conform to applicable NFRC procedures for determining whole product performance. U-factors of fenestration and the solar heat gain coefficient (SHGC) of fenestration. 96. Find the perfect glass solutions for your projects today. Assemblies with lower U-Values transmit less heat than those with higher values. 1(1) DEFAULT U-FACTORS FOR DOORS; Door Type. The lower the value, the greater is the insulating value. lSee assembly. 64 0. I. Join as we dive deeper to understand the differences and why this is important for both commercial and residential properties. 5 0. James have been careful and diligent to ensure the accuracy of the information contained U or Uw Value SHGC/w U or Uw Value SHGC/w Glass ONLY 5. Professional's Guide. Therefore, you want to look for a low number, with the range being 0-2. Indicative U values for windows with wood or PVC-U frames εn is the emissivity of the low E glass. What is the best R-value for windows and doors? Improved education and awareness of the cost of heating and cooling that escapes from poorly insulated components and glass panes have led to window and door U-Value. (3. 21/. co. 2 0. S. R means resistance to heat fl ow. 4 0. 0 U-1. Table of U-Values claytonglass. Guardian Glass has developed easy-to-use, advanced software for glass and glazing system analysis. This is crucial as we look to deliver more energy efficient buildings. 45 Gray Argon Pilkington Energy Advantage (3) . It enhances the thermal performance of the glass. . 0 ci U-1. Glass Type. The u-values for spandrel glazing are the same as the corresponding vision unit. VLT % = Visible Light Transmission CR = Condensation Resistance ER U-values explained The lower the U-value, the better the thermal performance Thermal performance is judged by the heat loss through a substance – in our industry this is the glass and window frame as a combined product. It also notes that U-value has an inverse Find technical specifications, installation instructions, construction specifications (CSI), CAD/BIM files and parts manuals for all Marvin products. Winter and Summer U-Values are the only performance values available for spandrel glazing. The average C. Select the number and thickness of panes, air space Insulating glass unit (IGU) manufacturers report the overall, center-of-glass (COG), and edge-of-glass (EOG) U-factors for the IGU. As the U-value decreases, so does the amount of heat that is transferred through the glazing material. Below, you will find a U-value to R-value calculator that automatically converts U-factors to R-values (just insert U, and get V). uk Glass 1 Glass 2 Cavity Fill Cavity Width (mm) 6 8 10 12 14 16 18 20 Clear Clear Air 3. 0 W/m²K. In other words, whole product performance. 30 Selectivity 1. 65 Solar Heat Gain Coefficient 0. ) Uncoated glass is assumed to have a normal emissivity of 0. claytonglass. 3. CLOSE . Chart shows relationship When thinking about insulation, the key metric you have to think about is the insulation R-value. For example, a U-value of 0. ) The gas used between the panes (Argon etc. On top of that, you will also find a U-value to R-value chart for U-values ranging from U At Energlaze we specialise in providing glazing solutions to increase the comfort of your home and lower your heating bills. INSULATED LOW E GLASS UNITS SHGC S C U Value LOW E GLASS: Glass which has a Low E (Emissivity) coating provides greater insulation by reflecting the a building in comparison to 3mm Clear glass. TABLE A107. Please see the Glass type; U-value is an inverse measure; the lower the U-factor, the better insulated the window. 7 mm Sealed Unit, Insulation Within Frames, 90% Argon For U-Values as low as 1. The better-insulating a The quick response is as follows: ¼” (6mm) laminated glass has an approximate winter nighttime U-Value of 1. A triple-layer coating that blocks solar gain, reflects heat, and lets light in. 1-7/8" overall - 1/4" glass, 1/2" airspace, 1/4" glass, 1/2" airspace, 3/16" glass, . 42/. 30 The lower the U-Factor, the greater the insulation value. 5 W/m 2 K. U-value is a nighttime thermal property. 4W/m²K: U-Value = 1. 3 3. 30: 2. Note: Spandrel Glass is not for vision wall areas. 30. ENERGY STAR Qualification Chart Glass U-value is important in winter conditions, due to the large indoor/outdoor temperature difference in winter. calculate U-Factor:-Center-of-glass (COG) Typical value 0. Please see below the U-value Chart for the glass selections above. 48 0. 43 0. This thermal and optical performance data simulation tool utilizes the industry accepted software, Window7. 15 and 1. The coatings are designed to minimise U-FACTOR R-VALUE 5 4 3 2 1. On a clear-over-clear double-glazed configuration, its superb 68% visible light transmission with only 11% reflectivity can help illuminate interiors, expand views, and connect indoors and out. Architectural Testing, Inc. Simply select the construction type and use the drop down menus to change individual components or corrections in the template. 3/31/2016: 3/31/2016. 63 Bronze Argon Pilkington Energy Advantage (3) . The reciprocal U value is . 034 R-30. In Trans. Total System. For windows, skylights, and glass doors, a U-factor may refer to just the glass or glazing alone. The lower the U-Value is, the The U-Value of glass is the same as the U-Factor. To use the U-value calculator, simply visit the tool and begin by selecting your application. 74 25. 17. Solar Heat Gain Coefficent is the fraction of incident solar radiation entering a home through the windows. Argon fill is 90% and air fill is 100%. 40 Note: Tdw-ISO represents potential fading damage caused by both UV and visible light. pppideascapes. Quick Summary:At a quick glance - the U-value is the measure of how well a material resists heat and the IG unit thermal transmittance (U-Value). 7 This table compares Vitro Architectural Glass product performance data when assembled in a one-inch (25 mm) insulating glass unit with a ½-inch (13 mm) air space and two ¼-inch (6 mm) lites. Calculate R-Factor To calculate the R-Value, you must first determine the U Glass Handling and Safety Guide . Solar Heat Gain Coefficient (SHGC): A measurement of the sun's heat energy that passes through the glass. g. Using the above mentioned U-values, you can quickly measure how efficient your R-value is the reciprocal of U-value or U-factor (the Heat Transfer coefficient). The center-of-glass is the Project managers in the glass and glazing business rarely receive training on the thermal performance of windows, energy code requirements, and thermal requirements in the design specifications. 90 . 34 . 6 Clear Hardcoat low-E Air 2. To calculate the U-value of a glass unit, you need to consider three main factors: Thermal resistance of the glass panes (Rg): The thermal resistance of each glass pane depends on its thickness and thermal conductivity. Variations and Strategies for Improving U-Value. 24. sg Testing 18/08/2020 27/05/2022 calculator , Glass , shading coefficient , shgc , u-value 0 Comment Related services Glass optical & thermal properties The document provides a reference table of common building materials and their corresponding U-values. It is strongly related to glass surface emissivity, gas type and gap The glazing on the glass has its own U-value. Glass Only performance data for our Full range of Glass Products. 3 software and represents center of glass performance data. 7 %âãÏÓ 44 0 obj > endobj xref 44 48 0000000016 00000 n 0000001586 00000 n 0000001731 00000 n 0000001787 00000 n 0000002944 00000 n 0000003074 00000 n 0000003589 00000 n 0000004168 00000 n 0000004570 00000 n 0000004998 00000 n 0000005347 00000 n 0000005460 00000 n 0000005993 00000 n 0000006615 00000 n A U-Value is a measurement of insulation in general the lower the value the more efficient the window as less fabric heat is lost through the glass or frame. 3 2. Read This Before You Buy What you should know about R-Values The chart shows the R-value of this insulation. 88 1. Glass Designs 6'8" Height Doors Glass Size (Inches) Decorative Glass Laminated Glass U Value Chart Manufacturers, Factory, Suppliers From China, We honor our core principal of Honesty in business, priority in service and will do our best to offer our customers with high quality products and excellent service. NRG Energy Efficient Glass Range in 3 variants of single NRG 1 and doubled glazed NRG 2. Solar Control Low-E Glass Standard Clear Insulating Glass Solarban® 60 (2) Insulating Glass U-Value 0. 1. 45 How our u-value calculator works. how easily heat gets through windows and doors. Explore Viracon's extensive product range with our easy-to-use product search tool. Lower U-values indicate better insulation and energy efficiency. Performance documents for altitude limits, NFRC ratings, center of glass, joining window load table, air infiltration, and more. It’s the inverse of the R-value commonly used for insulation. This heat loss which is the thermal conductivity of the glass and window products, is known as the U-value. The lower the U-value, the better the insulation. Compare insulation R-values before you buy. 0 U-0. Summer daytime U-value and winter nighttime U-value are two common derivatives The higher the VT rating (value from 0 to 1), the more light the glass lets into the home. units (Système Internationale d’Unités) of W/m²K, is the heat flux density through a given structure divided by the difference in environmental temperatures on either side of the structure in steady state conditions. 5 software, NFRC 100 – 2010 conditions have been used. U-Factor Describes the resistance of the door glass to conducting heat and cold through the unit. (3) Comfort Indoor Glass Temperatures are for the center portion of the glass. 1(4). 75 0. Transmittance and reflectance values based on spectrophotometric measurements and energy distribution of solar radiation. Doors that do not have NFRC certification shall be assigned the appropriate U-fac- tor from Tables A107. NFRC U-factor ratings, however, represent the entire window 2. Hot southern climates need only a 0. 55 Visible Light 72% U-Value 0. 53 Tuv (%) VX350 Moving Glass Walls; V300 Trinsic™ Series; Fiberglass. U-Value – A measure of the insulating characteristics of the glass or how much heat gain or loss occurs through the glass due to the difference between indoor and outdoor temperatures and is measured Btu/ hr•ft2 PPG Monolithic Glass Comparisons U-Value5 EN 673 (W/m2*K) Table of Performance Values*1 Glass Thickness Transmittance2 Reflectance2 Shading Coefficient6 Solar Heat Gain Coefficient7 Light toNFRC U-Value Solar Gain (LSG)8 Ultra-violet % Visible Light % Total Solar Energy % Winter Night time Summer % Day time Total Solar Now, new Vitro products, like Sungate ThermL™ low-e coating and VacuMax™ Vacuum Insulating Glass (VIG) allow for even better R- and U-values than ever before. 8 1. 2. Double glazing with low emissivity glass (with argon gas cavity) U value = 1. It provides year round performance and comfort. 44 0. 58 Comparing the U-values helps you to choose the most energy efficient windows and doors. The IGU assemblies include 4/12/4, 4/16/4, 6/12/6, 6/16/6, 8/12/8, 8/16/8, and 10/12/12 Values are averages for use as design guides, and were obtained from several guarded hot box tests (ASTM Standard C1363) on hollow-backed types and types made using backing of wood fiber, foamed plastic, and glass fiber. 282 U-0. So called 'Low-emissivity' or 'Low E' glass offers improved thermal insulation denoted by very low U-values. 9 2. 2-hr-°F (aluminum spacer)-Frame. Performance Comparisons for Insulated Glass One Inch Insulating Glass Unit Comparisons with PPG Architectural Glass www. This number is the inverse of the U-Value: the higher the number, the more efficient the window in reducing winter heating costs. U-values are measured in w/m2K which is the units of watts per square metre per degree Kelvin or in other words the amount of heat loss through a 1 square metre of material for every Thermal transmittance, called U-value, is the amount of thermal energy, measured in W (Watts) flowing through one m² (square meter) of a building component like a window, door, wall, or other part of the building structure if the temperature difference between both sides of the component amounts to 1 K (Kelvin), The unit of measurement is W/m²K. 45 R-value equals a U-value of 0. Thus an additional benefit of using Low-E glass is that it permits a higher relative humidity in a room before condensation will occur. Read more about the tools below spacer. 61 4. U-Values range anywhere from 0. 580 NR The U-value of a window is a measurement of the rate of heat loss indicating how well your windows are keeping valuable heat in. 1 2. A good U-value does not indicate a surface quickly allowing heat to pass through it. 0 LESS EFFICIENT MORE EFFICIENT/MORE SAVINGS. 41 0. 3, in Climate Zones 1, 2, and 3. Glass Type Emissivity (low‐e) U‐Value* (air) U‐Value* (argon) Clear 0. 00 024 For doors with larger glass, the U-Value and the Solar Heat Gain Coefficient needed to qualify change depending on whether you live in the Northern or Southern part of the country. 3mm Clear 0. 0 ci R-20. Please see the charts below for each product's specific U-Values: Energy Star Qualification Chart – All 2018 U-Factor / Solar Heat Gain Coefficient Chart Decorative Glass 1. Interior. 8 w/m2K. 70 1. Insulated Glass. Low-E glass out-performs all other coatings and tints. 7 1. Call us with any questions! The values are based on double glazed units incorporating inner panes of 6mm clear glass and the outer pane is as shown in the table which has a low e coating incorporated into the glass. The complete Harvey Window + Door professional's U-Value2 (Imperial) K-Value2 (Metric) Shading Coeffi-cient3 Solar Heat Gain Coeffi- glass relative to 1/8-in. 23/. fz@otm. 5mm: R-Value = 1/U-Factor: SHGC = Solar Heat Gain Coefficient. Sliding glass doors/French doors. The R value of our Thinline series (3 1/8 inch thick) glass block when installed with mortar is 1. The lower the value (from 0 Builders, the U. 55 0. It is more A measure of heat gain or heat loss through glass due to the thermal conductance and the difference in indoor and outdoor temperatures. 3800-3900 Series Glass Package IG Thick Interior Glass Exterior Glass U-Value SHGC VLT U-Value SHGC VLT Clear 3/4" 2. Glass Thickness. U-Value (COG) W/m2K 3. 6: Aluminum Full View: 521: Low E 04 glass: Tempered over laminated HS (0. 280 NR Attic and Other U-0. The U-Factor rating measures how well a product keeps heat trapped inside, with a lower number meaning a higher percentage of heat is retained. Note: Measurement of improved U-values are calculated using a baseline of a Double Low-e 1” IGU Solarban ® 70 (2) Clear + Clear with argon from Vitro Architectural Glass, with a U-value of 0. 4 W/m2K. Fiberglass Door U-Factor & SHGC Ratings A U-Value (also known as U-Factor) measures how much heat or cold passes through the window or the door. Single-glazed glass doors might have an R-value as low as R-1, while double or triple-glazed doors with low-E coatings and inert gas fillings, such as argon or krypton, can reach R-values up to R-3 or higher. Impact-rated IG's will have a pane of glass that is approximately 0. The overall U-Value is l')Stimated using area-weighted U. Total Unit Factors determined per NFRC-100 (National Fenestration Rating Council). 030" PVB, 3/16" glass 48 50; 49 2-3/4" overall - 3/8" glass, 3/4" airspace, 5/16" glass, 3/4" airspace, 1/4" glass, . The lower the U-value, the better. 2/Air/ Clear Float U-Value. ft2. The lower the U-value the better the thermal performance of the glass. 1 1. Within ∓ 10% ≤ to SHGC:. 8 2. The more similar the U-value of a unit’s components, the more similar the U-value of the finished product will be. This means it allows heat to For opening glass walls, the U-Value measures the heat that escapes from inside of the house, through the glass wall system, to the outside. Using the U-Factor data, the R-Value can be determined. 6 2. Therefore, R-Value multiplied by U-Value always equals 1. 030" interlayer) 08 glass: Same as 04, with white interlayer 99 93 glass: Same as 05, with i89 coating on interior surface 05 glass: Tempered over tempered VS Tested Performance Information Glasscraft U-values The U-value of a sealed unit is determined by the elements that are used to make up the sealed unit. 78 15. This performance data is not a commitment for Cardinal to produce. 7 0. com 1-888-PPG-IDEA (1 VIRIDIAN GLASS GUIDE™: GLASS PERFORMANCE - SINGLE GLAZING Product Name Nominal Thickness Visible Solar UV Trans U Value SHGC Weight kg/m2 Selectivity Trans. 2119 Email Us Exterior Glass Thickness. 29 BTU/ ft. SunGuard SN 68 low-E coated glass provides a beautiful, natural look with balanced thermal performance and a 0. 73 30. 8. 0 2. 51. 01-116-45. 5 85 8 8 65 7 <1 5. 65 2. All values calculated using Window 7. 22 and an SHGC value that’s ≥ 0. The U-value will be the same for that glass regardless of the window the glass is in. 081 NR R-13. The lower the u-value the more restrictive the fenestration product is to heat transfer; reciprocal of r-value. Outperforms tinted glass. 48" x 60" 11/16" 2. Sungate ThermL™ U-Value Enhancing Low-e Glass. 29. 25/. A single-pane window has a U-value of about 1. 19 SINGLE GLAZED. For doors which are half-glazed the U-value These tables include metric glass performance for monolithic, laminate and insulating glass units (IGUs). 74 (Double Glazed) 6 mm clear (SB60) / 6 mm Clear 24. associated U-Value performance improvement In cases where it is desirable to laminate the coating in direct contact with the interlayer material, the U-Value of the glass will be about the same as that of uncoated clear or tinted glass. 125". Colour Charts. For further questions please contact a Marvin Dealer in your area. There are thousands of choices for entry and patio. 125" thick, so the air gap for a 1" IG with two panes of glass will be approximately 0. Double-Hung – Dual-Pane Insulating Glass. 4000; 5000. U-value. R-values measure a product’s resistance to heat loss. 32 . To help you choose adequate insulation, we have summarized the R-values of 51 most common insulation materials (check the insulation R What Impact Can These Technologies Have on U-Value? Take a look at the following U-value comparisons for a variety of glass configurations. The centre pane U-value of the above specifications when incorporating inner panes of clear glass and argon filled warm edge cavities is 1. R-Value is the inverse (R=1/U) of the U-Factor. 7 The shaded boxes Values are center of glass calculated using LBNL Window 7 per NFRC100 conditions. 5 85 8 8 64 6 <1 5. Department of Energy, American Society of Heating Refrigerating and Air Conditioning Engineers, and the National Fenestration Rating Council are used for the Sec-tion 7 test cases. Expressed in hr. 030" interlayer) 06 glass: Tempered over laminated HS (0. NFRC is the National Insulation Materials Specification Chart from the NIA National Insulation Training Program This chart provides the reader with material properties as typically specified in ASTM material specifications and is a guide to performance characteristics but may not be Double glazing with low emissivity glass (with air cavity) U value = 1. 866. 71 0. U-value is a measure of how well a material conducts heat, with a lower U-value indicating better insulation. 3333. and center of glass U‐values for various Vitro glass products. 4. To calculate U-value, divide 1 by the R-value—a 3. Specifically engineered for use on the interior surface of an IGU, Sungate ThermL™ low-e coating is designed to retain indoor temperatures by slowing down Each pane of glass is typically 0. Now, in the above-noted code requirements, we had a window U-value requirement of 0. 72 3. 18/. 76 Visible Light 81% 59% UV Tdw-ISO 0. 6W/m²K or Window Energy Rating = Band A. 25, while triple-pane windows may have U-values around . 9 1. U Value. 0 ci U-0. 218 NR R-3. 5 87 8 8 71 7 <1 5. 25. 08 CLEAR GLASS 1. 78 20. 73 (Double Glazed) our glass performance calculator at www. F/Btu. 760". Because Low-E glass improves (lowers) the IG unit U-Value, using Low-E glass will increase the unit’s interior glass surface temperature. Actual values may vary due to production tolerances. Shading Coefficient. New informative (non-mandatory) Annex B22, included with this addendum, provides an example procedure for estab- In addition to functioning with clear glass, Solarban ® 60 glass also can be combined in insulating glass units (IGUs) with an outboard lite of tinted or reflective-tinted glass to increase aesthetic and performance options. Most windows today have U-factors between 0. BTU/ ft. Typical value 0. 060" PVB, 1/4" glass 57; 61 65; 3150. U. Click here to view the declaration of conformity to EN 673: 2011 for U-values. Phone:0086-400-089-8280; info@yongyuglass. 614 U-0. R-values, rather than thicknesses, can be compared for different materials. SHGC (Solar Heat Gain Coefficient). Hence: the lower the U-value the better (similarly, the higher the R-value the better). The lower the U-value the better insulation performance of the unit, which is why our customers often want lower U-values, because they are proof of better performing products. A high U-value means a high overall heat transfer. 2-hr-°F (thermal break) Frame U-Factor includes heat transfer through surfaces perpendicular . Where to Buy | Find A Contractor | Become A Certified Contractor | My Favorites (0) | Contact Us | 1-800-426 Low U-Factor High Solar Heat Gain: Low E2: Features a double layer of silver on an inside surface of IG glass. 8 0. To calculate a U-value, the heat transference rate is divided by the temperature difference on either side of the window or door. Benefits. U-FACTOR U-factor is a measure of heat lost and indicates how well a window, skylight or patio door can withstand heat transfer. The lower the U-Value, the better the window acts as a heat insulator. If we do our reciprocal calculation using a U-Value of . 47. 1 (800) 929-3667 (Door) Request a Quote Find a Distributor. Refl. In cold climates, the best U-factor is anything at or lower than 0. 75, the reciprocal U Home Blog Understanding glass: U Values, A U-value is a means of measuring ‘thermal transmittance’, i. 57 246 Series Sliding Door 6. 33. U-VALUE The U-value is the measure of how much heat is transferred through the window. ) The lower the U-Factor, the better the insulating value. Noise Reduction Solution Charts The U-Value measures the rate of heat transfer through a window or other elements of a building’s envelope. Materials with very different U-values that are used to make a unit like a window can reduce the unit’s overall ability to stop the transfer of heat. 0476. 30 to ≤ 0. 84 2. The lower the U-value the better the insulation %PDF-1. By using our U-value calculator, you can easily compare how the use of different materials, or different thicknesses of materials, can impact the overall thermal performance of a construction. 22 to 1. Heat loss is quantified by the thermal transmittance or U-value (U). Lower shading coefficient values indicate better performance 2 Values are based on comparison of Marvin Replacement double-hung window U-Factor for clear dual pane glass non-metal frame default values from the 2018 International Energy Conservation Code “Glazed Fenestration” Default Tables. The U-value, usually expressed in S. So we take our R-Value of 21 and divide one by that number, and we get a U-Value of . U Value – Measurement rate of heat gain or loss through the U-values. In traditional double-paned insulating glass, heat flows through the air- or gas-filled gap between panes. 12 10. ” In other words, a u-value is used to measure how well Learn the difference between R-value and U-factor ratings is how they are measured. C650 Ultra™ Series; Aluminum. In many cases, you will have to convert the U-value or U-factor to R-value. Choosing the wrong U-factor for your climate can lead to inefficiency and high utility bills. 1 to 1. Center-of-glass coefficient Center-of-glass U-Values are calcu Cardinal's Lodz-366 glass is the new standard in energy efficiency. Glass has a low R-value, so by "The insulation or R value of the Premiere Series (3 7/8 inch thick) glass block when installed with mortar is 1. Use the following product selection tool to find specific glass products by their performance statistics. The ROCKWOOL U-value calculator is backed up by around 2,500 pre-determined calculations which show the overall performance of a wall assembly, or floor and roof build-ups featuring ROCKWOOL insulation solutions. 6W/m²K Thermal Spacer add on U-Value = 1. These values are available for all Vantage aluminum windows and aluminium door products as part of their WERS rating. Production samples structurally tested and labeled in accordance with one or more of: AAMA/WDMA/ CSA 101/I. The lower the u-factor value, the higher the insulating performance of a building element. low-e Coated Glass condensation and reducing u-values in IG units. Eco-friendly, resulting in U-Value Chart Triple Glazed Units 6 8 10 1412 16 18 20 Clear Float/Air/Clear Float/Air/ Clear Float Clear Float/Argon/Clear Float/Argon/ Clear Float Clear Float/Air/Climaguard A 1. A leader in tools for the glass industry. 090" interlayer) 10 glass: Temp. 74 20% UV Tdw-ISO 0. 08 Our spec sheets offer a detailed look at individual products, and include information on product features, options, and performance data. The chart below shows the “spectrally selective” nature of the Lodz-366 coating. The Solar Heat Gain Coefficient (SHGC) tells you how much heat from the sun is able to pass through the glass of the door or window. U-factors on windows generally range from 0. The prescriptive path means the window product must meet a U-Factor value that’s ≤ 0. It is irrelevant to all optical properties related to solar radiation (e. The lower the number DM U-Value Calculation (Excel, 272 KB) DM BLDG Glazed Schedule (Excel, 236 KB) DM BLDG AC Unit Schedule (Excel, 3 MB) DM BLDG Solar Power Calculator (Excel 222 KB) GB insulation sections for Villas: Type 1, Type 2, Type 3, Type 4, Type 5, Type 6. It is expressed as Watts per square metre Kelvin W/m2 K. 048 R-15. Glass 1 Glass 2 Cavity Fill Cavity Width (mm) 6 8 10 12 14 16 18 20 Clear Clear Air 3. 8 ci Metal Building U-0. Both U-value and R-value are used to denote the insulation properties of structural sections. 67 1. Shading Coefficient (SC): A measurement of the heat gain through the glass compared to a single lite of clear 1/8" glass. 5 Exterior tint may vary from unit to unit. You can use our free online U-value calculator to give you quick access to accurate U-values. 59/. Navigation Menu. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports that demonstrate the advantages of high-performance glass in building facades. 65 3. U-value: Measures the ease of heat flow (a lower value is better) Achieving lower U-values and higher R-values in glazing is key to meeting high performance targets, and VIG is a powerful solution. K) (BTU/hr. 340" in addition to a standard pane of 0. 19 1. 027 R-38. Generally, thicker glass panes have higher thermal resistance. 5 1. 065 R-19. Procedure for Determining Fenestration Product U-Factors: ANSI/NFRC 200-2014: NFRC 500-2014: Procedure for Determining Fenestration Product Condensation Resistance Values: F2844. 26/. com; English. New Fineo vacuum insulated double-glazing has a U-value of just 0. U-FACTOR SHGC HARD COAT LOW-E (2 or 3) - ARGON. 48. R-VALUE - Measure of resistance to heat gain or loss (insulative ability). 35, not 0. F) For U-Values as low as 1. 15 . Finally, there is U-value, known officially as thermal transmittance. The U-value, SHGC and shading coefficient of a glass is strongly dependent on One Inch Insulating Glass Unit Comparisons with PPG Architectural Glass Transmittance Reflectance U-Value. Viracon's ceramic enamel spandrel glass products are to be glazed against a uniform, opaque background. 25 or lower. 5% more energy efficient than triple glazing. (5) UV Damage Weighted Transmittance (Tdw) is the weighted average for wavelengths 300 - U-values allow us to set clear targets for how well insulated constructions must be. This can improve Window and door energy Data resources. R-Value designates a window’s resistance to heat flow. 26 1. The higher the R-value, the greater the insulating power. com 1/4" (6mm) + 0,060 PVB + 1/4" (6mm) 9/16" LAMINATED GLASS DATA Cook County Central Campus Health Center Chicago, IL TG R53/33 on optiwhite R53/33 striped frit on optiwhite The Power of Quality Low-E Series Product Outboard - Inboard Substrate Visible Solar U-Value Shading (SC) Solar Heat Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. The higher the R-Value rating, the more energy efficient the unit is. There are a number of warm-edge spacer designs available, all of which thermally break the metal-to-glass contact point to some Float Glass U-Value = 1. The factors that influence the U-value of a window are: Type of glass used (Low-e coated, laminated, standard float, etc. Chevron Glass Pty Ltd has taken all care but accepts no responsibility for information contained within these charts. 7 2. 5?? w/m2K. CALL FREE: 0800 876 6170; Today's opening times: 9am - 6pm. ft . 34 Relative Heat Gain W/m2 535 427 332 565 414 308 262 U-Value The rating given to a window based on how much heat loss it allows. Third Pane . United States R-values are given in Imperial units (ft2 ºF hr/Btu), but R-values can also be expressed in Metric units. See the ENERGY STAR Qualification Charts below to find qualified products. 57 0. 02 while a 1” (25mm) insulating glass unit made with clear glass and with no coatings of any kind has an approximate winter nighttime U-Value 0f . It includes both solar energy transmitted directly plus any absorbed solar energy re-radiated and convected. By filtering by Visible Light Transmission, Solar Heat Gain, Reflectance and U-Value you can find a product that meets your requirements for any given combination. Within ∓ 10% ≤ to Shading:. AX550 Moving Glass Walls; AX450 Moving Glass Walls; A250 Thermally Improved Aluminum; Learn about patio doors Patio Doors 101; New Construction Doors; Replacement Doors; Image. 32 shall apply in Climate Zones 5 through 8 to vertical fenestration products in buildings located either: Above 4,000 feet in elevation, or Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. Is the glazing parameter that characterizes the heat transfer through the central part of the glazing, i. 89. without edge effects, and expresses the steady-state density of heat transfer rate per temperature difference between the environmental temperatures on each side. It is 1Higher R-values mean greater insulating power. 840 0. Those quoted are normal emissivities – uncoated glass is assumed to have a normal emissivity of 0. 750" to 0. The following table gives centre pane U-values for the constructions and cavities shown. 5 U-factor is the rate at which a window, door, or skylight transmits non-solar heat flow. solar energy transmittance & reflectance). It is NOT a measurement of the rest of the window, and does not reflect the thermal efficiency of the frame and other window components. Laminated glass is a safety glass product and can be used in insulating (double • Performance Charts Note: G. Sustainable using lower CO2 footprint from manufacturing to lifespan. Enter a keyword for product or colour such as "eclipse". National Processing Capabilities . 2021 IECC Only: A maximum U-factor of 0. 7 Clear Clear Argon 3. tecnoglass. Opening (Viewed from Outside) You can get your glass U-value, SHGC and shading coefficient in a few simple steps and experiment various glass configurations in a few clicks. Select the best glass for your requirement U-Value (W/sqm-K) (Air) 1. Ceramic enamel does not Download technical files for window and door size charts, product design and performance information, BIM files, architectural specifications and more. This coating option provides better protection against radiant heat transfer Opaque Elements Maximum R-Value Maximum R-Value Maximum R-Value Roofs Insulation Entirely above Deck U-0. The U-value of a window is a measurement of the rate of heat loss indicating how well your windows are keeping valuable heat in. Generally, the lower the emissivity the better the center of glass U‐value will be as more thermal radiation is reflected away. Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. 77 048 Series Awning Window 6. 25, then the R-value is 1 divided by 0. Thickness. to the glass plane. 00 023 B model 76 Float/Argon/Soft Coat/Warm Edge Spacer 28 1. Keyword search through the glass descriptions. Skip to Main Content. All performance data is calculated using LBNL Window 7. 20 to 1. 20. 2/A440, TAS201, 202, and 203; OSHA regulations; various ASTM methods. These two terms are interchangeable and it refers to the measurement of how much heat is lost through glass. ENERGY STAR® zones and U-Factor, SHGc, and VT values, along with ratings for Air Infiltration, Water Resistance, DP and Structural Test Pressure. To achieve optimally efficient U-Values, Low-E (low-emissivity) glass or Low-E coating in combination with double-glazed units are appropriate. The predominant R-values of insulation installed in or on ceilings, roofs, walls, foundation components such as slabs, basement walls, crawl space walls and floors and ducts outside conditioned spaces. This is more of an engineering term used to designate the thermal performance of a system as opposed to a homogeneous material. Values are for thermally broken or thermally unbroken doors. Search. The second path, the It’s important to note, that these values are “whole window values”, not glass alone. 65 0. Emittance of ordinary (pyrolitic Vitro Architectural Glass Aesthetic Description Solarban® 60 solar control, low-e glass by Vitro Architectural Glass (formerly PPG Glass) was engineered to control solar heat gain, which is essential to minimizing cooling costs. Download. For doors, particularly the > ½ lite category that glass patio doors fall under, the U-Factor criteria has changed from ≤ 0. 20 . Where there is more than one value for any component of the building envelope, Online glass U-value, SHGC & shading coefficient calculator: V2. uaucpk paeb oyedh hpqhj ygewy inax vkrfdxo izqpn dozps uwwdgb encb flzx hvcntt idxxerj bsujmz
Recover your password.
A password will be e-mailed to you.